Naturall+ ø3 Narrow implant

Used in one or two-stage surgery, the Naturall+ Ø3 implant has a "Morse taper" internal connection. Its narrow diameter at the apex makes this implant totally suitable for restorations of the central or lateral incisors when the roots converge.
logo_naturall3

Indications

• Reduced mesiodistal spaces.
• Fine crests.
• Post-extraction surgeries.
• Immediate loading.

This kit includes all the instruments necessary for carrying out the surgical protocol and the management of all bone densities for all lengths of Naturactis Ø3 and Naturall+ Ø3 implants.
IMG_Trousse_NN3_1

Reduced format for increased space in the sterile field and the autoclave.

One kit for 2 implant systems.

Readability of sequences due to the presentation of the instruments in order of use and the protocol table..

IMG_Trousse_NN3_2

Connection common to the Naturactis Ø3 implant.

IMG_Implants_NN3_connexion

Morse taper internal connection

  • Impermeability of the prosthetic seal.x
  • Stability of the implant/component assembly.
  • Precision of the orientation of the prosthetic elements.

Connection common to the Naturactis Ø3 implant

  • Streamlining of stocks of prosthetic components for simplified component management between the practice and the laboratory.

Juxtacrestal positioning

IMG_Implants_naturall3_juxacrestal
  • Better visibility and probe access.
  • Ease of control during sealing and over the long term.
  • Machined microthreads at the neck with a Ra of 0.2 μm: better mucosal attachment by orientation of collagen fibres.

Microthread synchronous with the macrothread

IMG_Implants_microfilet_synchrone
  • Insertion without tearing the cortical bone.
  • Stabilisation of the cortical bone by micro-stimulation.
  • Optimised primary anchorage.
  • Greater resistance to axial loads.
  • Reduction is shearing constraints at the bone/implant interface.

Double asymmetrical thread

IMG_Implants_double_filet_asymetrique
  • Homogeneous distribution of masticatory forces.
  • Excellent primary stability immediately after implant placement.
  • Decreased heating of the bone and insertion time.

Central protusion between threads

IMG_Implants_protrusion
  • Contact surface with bone tissue increased by 15%.
  • Facilitates osteogenesis.
  • Activates cell reconstruction.

Implant body is conical

IMG_Implants_naturall3_conicite
  • Optimised implantation near curved roots.
  • Optimised primary stability.
  • Limits apical compression.
  • Atraumatic insertion in sensitive areas (sinus, dental nerve).

Narrow active apex

IMG_Implants_naturall_apex
  • Vent closer to the apex to improve the self-tapping effect of the spirals.
  • Threading leads from apex for improved self-tapping capacity of the implant and better apical fixation.
  • Safe to use in at-risk areas.

Proven STAE® surface condition

IMG_Implants_STAE
  • Titanium oxide micro-sanding.
  • Etching with nitric and hydrofluoric acids.
  • 23 years of clinical experience.

Direct mandrel implant driver

IMG_Implants_naturall3_prise_directe
  • Time saved during surgery.
  • Better visibility of the placement level and the orientation of the connection.
  • Gingival height provided.