Natea+ The versatile implant

The Natea+ implant is an implant to be placed in 2 surgical stages based on the latest scientific data acquired in implantology to limit any marginal bone loss and optimise the primary anchorage. Its dimensions (straight neck) and its slightly supracrestal positioning can meet the requirement of most clinical cases and facilitate the achievement of a durable aesthetic result (localisation and control of the prosthetic seal).

Indications

• Mandibular arch.
• All bone densities, especially high bone densities.

Surgical kit Ø3.6 - 4.1 - 4.8.

This kit includes all the instruments necessary to carry out the surgical protocol and the management of all bone densities for Natea+ and Aesthetica+2 Ø 3.6 - 4.1 - 4.8 – 6 implants.

Reduced format for increased space in the sterile field and the autoclave.

One kit for 2 implant systems: Natea+ / Aesthetica+².

Readability of sequences due to the presentation of the instruments in order of use.

Colour coding of plugs and stiffeners according to implant diameters.

Natea+ Ø6 supplementary surgical kit.

This kit includes the instruments complementary to the kit reference ANCPT 00 for surgery and the management of all bone densities for all lengths of Natea+ Ø6 mm implants.

Simple and compact.

Reduced format for increased space in the sterile field and the autoclave.

Readability of sequences due to the presentation of the instruments in order of use and the protocol table.

Unique connection common to Naturactis+ and Naturall+ implants

Impermeability of the prosthetic seal

  • Better sealing of the restoration.
  • Stability of the implant/component assembly.
  • Precision orientation of prosthetic elements.

Connection common to Naturactis+ and Naturall+ implants

  • Components for simplified component management between the practice and the laboratory.

The same connection for all implant diameters

  • The choice of gingival platform does not depend on the choice of implant diameter.

A single prosthetic range and 4 prosthetic platforms

  • Simplification of the treatment plan, surgeries and prosthetic constructions.

Juxtacrestal placement

  • Better visibility and probe access.
  • Facilitates control during sealing and over the long term.
  • Machined microthreads at the neck with a Ra of 0.2 μm: better mucosal attachment due to orientation of collagen fibres.

Microthread synchonous with the macrothread

  • Insertion without tearing the cortical bone.
  • Stabilisation of the cortical bone by micro-stimulation.
  • Optimised primary anchorage.

Double asymetrical threading

  • Homogeneous distribution of masticatory forces.
  • Excellent primary stability immediately after implant fitting.
  • Decreased heating of the bone and insertion time.

Central protusion between threads

  • Contact surface with bone tissue increased by 15%.
  • Facilitates osteogenesis.
  • Activates cellular reconstruction.

Engaging, atraumatic apex

  • Vent closer to the apex to improve the self-tapping effect of spirals.
  • Threading from apex for greater self-tapping capacity of the implant and improved apical fixation.
  • Completely safe to use.

Proven STAE® surface condition

  • Titanium oxide micro-sanding.
  • Etching with nitric and hydrofluoric acids.
  • 23 years of clinical experience.

Direct mandrel implant driver

  • Time saved during surgery.
  • Faciliates visibility of placement level and orientation of the connection.
  • Gingival height provided.